    摘要:

    母乳低聚糖(Human Milk Oligosaccharides,HMOs)作为新食品营养强化剂,其检测方法的准确性受到广泛关注。为优化7种HMOs的高效液相色谱法,该研究对比前处理和仪器参数对其定性定量检测的影响。婴配乳粉等11种食品用水复溶稀释后,经淀粉葡萄糖苷酶和β-半乳糖苷酶酶解净化,经荧光标记后收集上清液,流动相为乙腈和甲酸铵溶液(50 mmol·L-1 ,pH值 4.2±0.1),激发波长和发射波长分别为330 nm和420 nm,以昆布三糖为内标进行定量分析。2’-岩藻糖基乳糖在5~500 mg·L-1、其他6种HMOs在1.5~150 mg·L-1范围内线性关系可达0.99999,加标回收率为90.62%~109.71%,相对标准偏差小于5.23%。7种HMOs的检出限为2.00 mg/100g(固)和0.20 mg/100g(液);定量限为5.00 mg/100g(固)和0.50 mg/100g(液)。本方法不适用于含有低聚异麦芽糖的食品中双岩藻糖基乳糖的测定。使用优化后的方法检测市售婴配和特医等食品222件,发现目前食品中多以添加2’-岩藻糖基乳糖和乳糖-N-新四糖为主,但3’-唾液酸化乳糖的检出率较高。该法前处理简单,灵敏度高,具有良好的重复性,可用于食品中7种HMOs的检测,为后续国家标准的制定提供理论基础。

    Abstract:

    As novel food nutritional fortifiers, human milk oligosaccharides (HMOs) have attracted widespread attention regarding the accuracy of their detection methods. To optimize the high-performance liquid chromatography (HPLC) method for seven HMOs, the effects of sample preparation and instrumental parameters on their qualitative and quantitative analysis were investigated in this study. After redissolution and dilution with water, 11 types of food samples were treated with starch glucosidase and β-galactosidase for purification. The supernatants were collected after fluorescent labeling. The separation was performed using acetonitrile and NH4COOH (50 mmol·L-1, pH 4.2 ± 0.1) as the mobile phases. The excitation and emission wavelengths were 330 nm and 420 nm, respectively. The quantification was carried out using laminaritriose as an internal standard. The linear correlation of 2’-fucosyllactose was up to 0.99999 within the range of 5-500 mg·L-1, and that of the other 6 HMOs was up to 0.99999 within the range of 1.5-150 mg·L-1. The recovery rate was 90.62%-109.71%, and the relative standard deviation was less than 5.23%. The limits of detection (LOD) of the 7 HMOs were 2.00 mg/100g (solid) and 0.20 mg/100g (liquid), and the limits of quantitation (LOQ) were 5.00 mg/100g (solid) and 0.50 mg/100g (liquid), respectively. This method is not applicable to the determination of difucosyllactose in foods containing isomaltose oligosaccharide. Using the optimized method, 222 batches of commercially infant formula and special medical foods were tested. Currently, most of them are mainly supplemented with 2’-fucosyllactose and lacto-N-neotetraose, while lacto-N-neotetraose was detected at a relatively high frequency. This method has a simple pretreatment process, high sensitivity, good repeatability. It can provide a theoretical foundation for the formulation of the subsequent national standards.

    参考文献
    相似文献
    引证文献
引用本文
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-08-09
  • 最后修改日期:2026-10-28
  • 录用日期:2026-10-28
  • 在线发布日期:
  • 出版日期:
文章二维码